BPGVW - 3105, ZINC STEARATE MOLD RELEASE

Product Identification

Product ID:3105, ZINC STEARATE MOLD RELEASE
MSDS Date:03/11/1986
FSC:6850
NIIN:00N030912
MSDS Number: BPGVW

Responsible Party
CROWN INDUSTRIAL PRODUCTS CO INC
12603 STATE LINE RD
HEBRON, IL 60034
US

Emergency Phone: 815-648-2424;815-338-2141

Info Phone: 815-648-2424

Preparer: ROBERT E. BAYTON

Cage: 92381

Contractor
CROWN INDUSTRIAL PRODUCTS CO
350 HEBRON, IL 60034 US

Telephone: 815-648-2424

Cage: 92381

Ingredients

DICHLORODIFLUOROMETHANE; (PROPELLANT 12) (SARA III)

CAS: 75-71-8

RTECS: PA8200000

Fraction By Weight: 31-50%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHANE, 1,1,1-TRICHLORO-; (METHYL CHLOROFORM)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 51-70%

OSHA PEL 350 PPM;450 STEL

ACGIH TLV: 350 PPM;450 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL:MAY CAUSE IRRIT OF RESP
SYS, DIZZ,NAUS, LIGHTHEAD/HDCH. PRIMARILY CNS DEPRESS. INGEST:MAY
CAUSE CHEM PNEUM IF ASPIR INTO LUNGS. EYE:LIQ SPLASHED INTO EYES
CAN RSLT IN DISCOMFORT, PAIN/IRR IT. SKIN: PRLNGD/RPTD CONT CAN
CAUSE IRRIT/DERM. CHLOROCARBON/CHLOROFLUOROCARBON (CFC) MATLS HAVE
PRDCD (EFTS OF OVEREXP
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:SENSIT OF MYOCARDIUM TO EPINEPHRINE IN
LAB ANIMALS AND COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS
(E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR
LIFE-SUSTAINING USES IN HUMANS AC UTELY/CHRONICALLY EXPOS TO
CHLOROCARBONS/CFC'S .CHRONIC: PRLNGD EXPOS ABOVE OSHA PEL MAY RSLT
IN KIDNEY/LIVER DMG.
Medical Cond Aggravated by Exposure:MAY INCREASE MYOCARDIAL
IRRITABILITY. AVOID EPINEPHRINE OR SIMILAR DRUGS IF AT ALL
POSSIBLE.

First Aid

First Aid:CALL A PHYSICIAN. EYE: WASH WITH WATER FOR AT LEAST 15
MINUTES OR UNTIL IRRIT SUBSIDES. SKIN: REMOVE ALL CONTAMINATED
CLOTHING AND WASH SKIN WITH SOAP AND WATER. INHALATION: REMOVE FROM
EXPOSURE IMMED IATELY. IF BREATHING IS IRREGULAR OR STOPPED, BEGIN
ARTIFICIAL RESPIRATION AND ADMINISTER OXYGEN. INGESTION: DRINK
PLENTY OF WATER. DO NOT INDUCE VOMITING.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS
.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:VAP CONC IN CONFINED/POORLY VENT AREA CAN
BE IGNITED UPON CONT W/SPARK, FLAME/HIGH INTENSITY SOURCE OF
HEAT.THIS CAN OCCUR AT CONC RANGING FROM 7-15%(SUPP DATA)

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE ALL SOURCES OF
IGNITION. CLEAN UP WITH INERT MATERIALS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE IN DIRECT SUNLIGHT, NEAR
OPEN FLAMES OR AT TEMPERATURES EXCEEDING 120F. USE ONLY AS
DIRECTED.
Other Precautions:INTENTIONAL MISUSE BY DELIB CONC VAPS/INHALING
CONTENTS CAN BE HARMFUL/FATAL.NO SMOKING IN AREA OF USE.DO NOT USE
IN GEN VICINITY OF ARC WELDING/OPEN FLAMES/HOT SURFS.HEAT &/OR UV
RADIA MAY CAUSE FORM OF CHLORIDES/FLUORIDES/PHOSGENE .

Exposure Controls

Respiratory Protection:WEAR NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . RESPIRATORY PROTECTION PROGRAM SHOULD BE
IN ACCORDANCE WITH 29 CFR 1910.134.
Ventilation:LOCAL EXHAUST IS ADEQUATE.
Protective Gloves:POLYETHYLENE OR NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING AND EQUIPMENT: SEE 29
CFR 1910.132 & 133.
Work Hygienic Practices:WASH SKIN WITH SOAP AND WATER.
Supplemental Safety and Health
HMIS(LEVIEN) HAS ASSIGNED HCC OF G1 BASED ON
1,1,1-TRICHLOROETHANE(POISON-6.1,III)/FREON R-12(GAS,2.2).EXPLO
HAZ: BY VOLUME. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE
CHLORIDES, FLUORIDES & PHOSGENE . VAPOR PRESSURE: 45-50 PSIG
AEROSOL.

Chemical Properties

HCC:G1
Vapor Pres:SUPP DATA
Vapor Density:>1
Spec Gravity:<1
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WHITE/ETHEREAL ODOR.
Percent Volatiles by Volume:>95

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTAMINATION WITH CAUSTIC SODA, CAUSTIC POTASH OR OXIDIZING
MATERIALS.
Stability Condition to Avoid:OPEN FLAMES, SPARKS, ELECTRICAL ARCS.
Hazardous Decomposition Products:HYDROGEN CHLORIDE AND POSSIBLY TRACES
OF PHOSGENE. THERM DECOMP PRODS MAY INCLUDE CHLORIDES, FLUORIDES &
PHOSGENE.

Disposal

Waste Disposal Methods:DO NOT PUNCTURE OR INCINERATE. EMPTY CONTAINERS
MAY BE DISPOSED OF THROUGH NORMAL CHANNELS. FULL OR PARTIALLY
FILLED CONTAINERS ARE CONSIDERED HAZARDOUS WASTE. DISPOSE OF IN
ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.